AquiTron AT-APA alarm panel with leak location, 4 circuits of 100 m each
- Default short description
Up to four individual detection circuits, each with 100 meters of sensor cable, or up to 6 point sensors can be monitored. The AT-APA's metal housing can be easily mounted on a wall or other flat surface. The panel has a large touch screen and a 90 decibel audible alarm. It provides visual and audible indications for stand-alone applications. Several options for connecting external devices are available as standard. Full connectivity is available via ModBus or via "Leak Detected" and "Fault Detected" (wire break or power loss) voltage-free relays on each of the four channels for connection to BMS and/or other remote monitoring systems. In addition, full remote control and monitoring is available via a web server connected via RJ45 or Wi-Fi. The AT-APA panel operates from 100 to 230 V AC (50/60 Hz), 24 V AC and 12/24 V DC. Battery backup for 24-hour operation in the event of a power failure can be easily provided with the AT-PSU-12-1 add-on.
SIMPLE OPERATION
This compact module is suitable for integration into the building's computer network, and in the event of a leak, it will automatically send an alert to notify the staff of the problem. The module can be easily configured and data can be checked locally via the touch screen or remotely via the built-in web server. Any leakage is displayed on the module's touch screen and a buzzer is activated. Automatic alarms are sent via SNMP or e-mail, and the alarm relay is enabled. All alarm data can be viewed remotely. All alarms are stored in the module's memory with time stamp and details. The location of the leak can be easily identified on a PDF diagram that can be loaded into the alarm module. AT-APA can be easily integrated into any building management system by configuring the relay contacts or reading the standard Modbus TCP / IP register.
CONSTRUCTION
Capable of monitoring up to four individual detection circuits. The AT-APA's metal housing can be easily mounted on a wall. The panel has a large touch screen and a 90 decibel audible alarm. Provides visual and audible indications for stand-alone applications. Several options for connecting external devices are available as standard. Full connectivity is available via BACNet, ModBus, or via "Leak Detected" and "Fault Detected" (wire break or power loss) volt-free relays on each of the four channels for connection to BMS and/or other remote monitoring systems. In addition, full remote control and monitoring is available via a web server connected via RJ45 or Wi-Fi. The AT-APA panel operates from 100 to 230 V AC (50/60 Hz), 24 V AC and 12/24 V DC. Battery backup for 24-hour operation in the event of a power failure can be easily provided with the AT-PSU-12-1 add-on.
APPLICATIONS
The AT-APA is ideally suited for projects where cost-effective solutions for precise leak detection are required, such as commercial spaces or individual residential properties. Suitable areas: server rooms, data centers, large catering outlets, elevator shafts, basements, technical rooms, tanks and pumping stations, etc.
SAMPLE APPLICATION 1
Up to 4 detection zones, all individually monitored for leak location.
- Zone 1 Perimeter coverage commonly used to protect against perimeter leaks or leaks from adjacent rooms.
- Zone 2 Spot probes sensing water located at the lowest points or in embankment areas or drip trays.
- Zone 3 HVAC perimeter protection when chilled water or condensate pipe is in front of units.
- Zone 4 HVAC perimeter protection when the chilled water or condensate pipe is fed from above and the high level sensor wire in the drip tray or attached to the pipes.
EXAMPLE APPLICATION 2
The AT-APA control panel can be located away from the monitored areas, i.e. in a security, control or BMS room.
- Sensor wires and probes can be combined in the same sensor circuit.
- The TT1000 water detection sensor cable, is available in lengths of 1, 3, 5, 7.5, 15, 25 meters.
- Modular connection cable is available in lengths of 1, 3, 5, 10, 15, 25 meters.
- Modular extension cables are available in lengths of 5, 10, 15, 20, 25 meters.
- Select components with plastic connectors (suffix PC for TT1000 and TT1100) and with suffix MC for metal connectors for TT5000.
"A" shows a TT-MBC modular manifold in a sensor circuit. The branch connector is wired, so the connected branch appears in series, the middle leg first. The branch connector also adds a simulated sensor wire length of 4.5 meters on each leg to provide a clear division between areas or sections of sensor wire. The number of branch connectors is limited only by the total length of the sensor circuit.
"B" shows where the sensor circuit jumps to a new room or area and the TT-WL area separator is used. The area seprator simulates a 4.5-meter sensor cable, so the "System Map" will show clear divisions between separate areas.
"C" shows the modular extension cable and connection cable used at the beginning of the system in the direction from the panel. They are also used between different sections of sensor cables. Maximum of 500 meters per circuit.
"D" represents the TT-MET modular termination used at the end of each sensor cable circuit. When using AT-PROBE-TS, end-of-line loops must be installed on the last probe.
RELATED PRODUCTS
- 3675 - AT-PSU-12-1 Emergency power supply for power supply / battery pack
- 3700 - AT-BAT 7 Ah battery pack
- 2028 - AT-APA-HTS Humidity / temperature sensor
- 2335 - AT-RAP Remote alarm panel (230 V AC)